Ohaus CD-33 Indicator User Manual Page 1

Browse online or download User Manual for Scales Ohaus CD-33 Indicator. Ohaus CD-33 Indicator User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 47
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
1
CD Indicators
INSTRUCTION MANUAL
Models CD-31 and CD-33 Indicators
Ohaus CorporationOhaus Corporation
Ohaus CorporationOhaus Corporation
Ohaus Corporation
29 Hanover Road
Florham Park, NJ
07932-0900
Page view 0
1 2 3 4 5 6 ... 46 47

Summary of Contents

Page 1 - INSTRUCTION MANUAL

1CD IndicatorsINSTRUCTION MANUALModels CD-31 and CD-33 IndicatorsOhaus CorporationOhaus CorporationOhaus CorporationOhaus CorporationOhaus Corporation

Page 2

10CD Indicators• Plug the AC adapter to an appropriate power supply. Power is now applied to the Indicator.• The Indicator performs a self-test. This

Page 3

11CD IndicatorsThe indicator itself has three basic menus; each is selected by front panel buttons marked Mode, Units and Setup.Mode ButtonThe Mode bu

Page 4 - TABLE OF CONTENTS

12CD Indicators RS232Baud 300, 600, 1200, 2400, 4800,9600Parity None, -E-, -Odd-, -0-, -1-Data 7 or 8Stop 1 or 2Lock ON/OFFExit

Page 5 - TABLE OF CONTENTS (Cont.)

13CD Indicators2.6 Scale Base Setup (Cont.)Review the specifications of the scale base to be used with the Indicator. Make sure the settings you sele

Page 6 - OVERVIEW OF CONTROLS

14CD Indicators• Press Enter button, LOCK OFF is displayed, selecteither ON or OFF using or buttons, thenpress Enter button SAVED is momentarily

Page 7

15CD Indicators3. SETTING UP YOUR INDICATOR3.1 Setting Date and TimeYour Indicator provides date and time data which can be viewed on a computer or pr

Page 8

16CD Indicators3.2ReadoutThe Readout menu is used to adapt the Indicator to environmental conditions. It contains five submenus: Stable,Auto 0, Filte

Page 9

17CD IndicatorsProcedure• Press the Setup button, SCALE is displayed.• Press button until READOUT is displayed.• Press Enter button, STABLE is displ

Page 10

18CD Indicators3.3 Good Manufacturing Practices (GMP) DataThe GMP Data submenu enables the storage of a user identification number (7 digits), a proje

Page 11 - Scale Menu

19CD IndicatorsProcedureTo select any of the items in the GMP Set menu, proceedas follows:3.4Good Manufacturing Practices (GMP) SetGood Manufacturing

Page 12 - 2.6 Scale Base Setup (Cont.)

2CD IndicatorsIEC1010-1 & EN60950:1992 Safety RegulationsIEC1010-1 & EN60950:1992 SicherheitsbestimmungenIEC1010-1 & EN60950:1992 Consigne

Page 13 - Procedure

20CD Indicators3.5PrintThe Print menu provides a number of options which can be turned ON or OFF. It contains 8 submenus: Auto Print,Inter, Stable, Nu

Page 14

21CD Indicators3.6 RS232The RS232 menu provides communication parameters which can be set to accommodate external printers or comput-ers. It contains

Page 15

22CD Indicators3.7 Legal for Trade (LFT)Legal for Trade (LFT) is a software controlled option which can be set to LFT LOCK. When LFT LOCK is set ON

Page 16

23CD Indicators3.8 ModeThe Mode submenu permits the selection of 6 modes which can be turned ON or OFF. These modes are: Weigh,Percent, Count, Animal

Page 17 - 3.2Readout (Cont.)

24CD Indicators3.9 UnitsThe Units submenu permits the selection of the measuring units which can be turned ON or OFF and locked.Procedure• Press the S

Page 18

25CD IndicatorsLFT is OffMode MenuWEIGH= OnPERCENT= OnCOUNT= OnANIMAL= OnCHECKWEIGH = OnEXP WGT= OffLock Switch is OffMenu LocksRS232= OffREADOUT=

Page 19

26CD Indicators3.11 Custom UnitCustom Unit is enabled when Custom Unit Setup under Units Menu is turned ON. This feature can be used to createyour ow

Page 20 - 3.5Print

27CD Indicators3.11 Custom Unit (Cont.)Procedure (Cont.)• Press Enter button, SAVED is momementary dis-played followed by LSD. There are 6 LSD (least

Page 21 - 3.6 RS232

28CD Indicators4.1 CalibrationModel CD-31 and CD-33 Indicators offer a choice of four calibration methods: Span, User, Linearity, and CalTestTM.•Span

Page 22 - 3.7 Legal for Trade (LFT)

29CD Indicators4.1.1 Span CalibrationSpan calibration requires a mass equal to 100% of the scale base capacity.Procedure• Press the Setup button, SCAL

Page 23 - 3.8 Mode

3CD IndicatorsNOTE: THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A CLASS A DIGITALDEVICE, PURSUANT TO PART 15 OF THE FCC RU

Page 24 - 3.10 Global

30CD Indicators4.1.2 User CalibrationUser calibration is used when it is desired to calibrate the Indicator using a mass of known value from 10% to 10

Page 25 - 3.10 Global (Cont.)

31CD IndicatorsProcedure• Press the Setup button, SCALE is displayed.• Press button UNTIL CAL is displayed.• Press Enter button, CAL TYPE is display

Page 26 - 3.11 Custom Unit

32CD Indicators4.1.4 Calibration TestCalibration test feature allows a check of a known calibration mass against the last stored calibration informati

Page 27

33CD Indicators4.1.5 Calibration GMP PrintoutIf any option in the GMP Set Menu is turned On, GMP automatically prints data after calibration is comple

Page 28 - Calibration Masses

34CD Indicators4.2 WeighingThe Indicator is shipped with kilograms only enabled. When the Indicator is to be used with other Type Approved/Legalfor T

Page 29 - 4.1.1 Span Calibration

35CD Indicators4.2.2 Preset TaringPreset taring is used to enter a tared weight via the numerical keypad. If a container's weight is known, the

Page 30 - 4.1.2 User Calibration

36CD Indicators4.3 Percent WeighingPercent Weighing is enabled only when Percent is turned ON in the Mode submenu under Setup. Percent weighingpermit

Page 31 - 4.1.3 Linearity Calibration

37CD Indicators4.4Parts CountingParts Counting is enabled only when Count is turned ON in the Mode submenu under Setup and selected with theMode butt

Page 32 - 4.1.4 Calibration Test

38CD IndicatorsProcedure• Press the Mode button, WEIGH is displayed.• Press or button until ANIMAL is displayed.• Press Enter button to continue,

Page 33 - Calibration Test Printout

39CD IndicatorsProcedure• Press the Mode button, WEIGH is displayed.• Press or button until CHECK W is dis-played.• Press Enter button to continu

Page 34 - Weighing Procedure

4CD IndicatorsTABLE OF CONTENTSOVERVIEW OF CONTROLS ...

Page 35 - 4.2.2 Preset Taring

40CD Indicators4.7 Printing DataPrinting data to an external computer or printer requires that the communications parameters in the Setup menu, Print

Page 36 - 4.3 Percent Weighing

41CD IndicatorsCommandCommandCommandCommandCommandCharacterCharacterCharacterCharacterCharacterDescriptionDescriptionDescriptionDescriptionDescription

Page 37 - 4.4Parts Counting

42CD IndicatorsCommandCommandCommandCommandCommandCharacterCharacterCharacterCharacterCharacterDescriptionDescriptionDescriptionDescriptionDescription

Page 38 - 4.5 Animal Weighing

43CD Indicators5 CARE AND MAINTENANCETo keep the Indicator operating properly, it should be kept clean and free from foreign material. If necessary, a

Page 39 - 4.6 Checkweigh

44CD Indicators5.2 Error Codes ListError Codes ListThe following list describes the various error codes and which can appear on the display and the su

Page 40 - 4.7.2 Output Formats

45CD Indicators5.5 AccessoriesDescription Ohaus Part No.Adjustable Column 80250632Wall Mounting Bracket 80250633Scale Base Mounting Plate 80250634RS23

Page 41 - 4.7.2 Output Formats (Cont.)

46CD IndicatorsLIMITED WARRANTYOhaus products are warranted against defects in materials and workmanship from the date of deliv-ery through the durati

Page 42

47CD IndicatorsOhaus Corporation29 Hanover Road,Florham Park, NJ 07932, USATel: (973) 377-9000,Fax: (973) 593-0359With offices worldwide.P/N 80'

Page 43 - 5.1 Troubleshooting

5CD IndicatorsTABLE OF CONTENTS (Cont.)4. OPERATING YOUR INDICATOR ...

Page 44

6CD IndicatorsOVERVIEW OF CONTROLS 3 4 256 8910 711 No. Designation Function 1 Mode button Selects standard weighing, percent, parts counting,

Page 45 - 5.4 Replacement parts

7CD IndicatorsOVERVIEW OF DISPLAY INDICATORS No. Function123456789101112131415161718 No. Function 1 Use (Pointer Group) keys to change -

Page 46 - LIMITED WARRANTY

8CD Indicators2. INSTALLATION2.1Unpacking and CheckingOpen the package and remove the instrument and the accessories. Check the completeness of the d

Page 47

9CD Indicators2.3 Connecting the Indicator to aScale Base• Turn the Indicator over.NOTE:Check the wiring instructions of your scale base.• The Termina

Comments to this Manuals

No comments