RE Series Price Computing Scale RE-C (with Tower) Model RE Model
EN-8 RE Series display will show the Tare as a negative net value (with the pan empty), and the PT and NET annunciators will
RE Series EN-9 4.9 PLU Function (Price Lookup) The PLU function is used for quick storage and recall of the unit price and t
EN-10 RE Series 3. If set to store two PLU’s per M-key, press and hold the desired M-key until the long beep, then quickly p
RE Series EN-11 3. The Weight display will show “Total”, the Unit Price display will show “1” (the number of weighings), and
EN-12 RE Series 5. SCALE SETTINGS 5.1 Accessing the User Setup Mode Press [PLU] [4] [4] [4] [4]. “oP ” will be displayed,
RE Series EN-13 6. CALIBRATION AND SEALING 6.1 Calibration For best results, calibrate the scale at regular intervals. Te
EN-14 RE Series 6. Span Calibration Sequence: Display Description Actions Lb Calibration Unit: kg or lb Press [FIX] to se
RE Series EN-15 6.2 Type Approval Sealing After the scale has been found to comply with local regulations by respective appr
EN-16 RE Series 7. MAINTENANCE 7.1 Cleaning Comply with safety precautions when cleaning and maintaining the scale • T
RE Series EN-17 7.2 Troubleshooting The following table lists common problems, possible causes and remedies. If the problem
EN-18 RE Series 8. TECHNICAL DATA 8.1 Specifications Model RE15US RE30US RE15CUS Capacity x Readability 30 lb x 0.01
RE Series EN-19 8.2 Drawings Memory Keys Pull-out Tab Template: 13.6” / 345 mm13.5” / 342 mm17” / 432 mm 4.5” / 1
EN-20 RE Series 8.3 Compliance Compliance to the following standards is indicated by the corresponding mark on the product.
RE Series EN-21 LIMITED WARRANTY Ohaus products are warranted against defects in materials and workmanship from the date of
Ohaus Corporation 19A Chapin Road P.O. Box 2033 Pine Brook, NJ 07058, USA Tel: (973) 377-9000 Fax: (973) 593-0359 W
RE Series EN-1 1. INTRODUCTION...
EN-2 RE Series 1. INTRODUCTION This manual contains installation, operation and maintenance instructions for the RE Series sc
RE Series EN-3 Install the weighing pan as illustrated below, with the pan properly aligned. 2.3 Selecting the Location
EN-4 RE Series When running on batteries, the battery cursor is displayed and indicates the state of the battery power: B
RE Series EN-5 3. OVERVIEW OF CONTROLS AND FUNCTIONS 3.1 Control Panel 3.2 Customer Display 1 Weight display 2
EN-6 RE Series 3.3 Keys and Display Indicators • Short press turns the scale on; long press turns the scale off • Activa
RE Series EN-7 4. OPERATIONS 4.1 Turning the Unit On and Off Short-press [ON/OFF] to turn the scale on; long-press to turn
Comments to this Manuals