Digital Output ConnectionsDigital Output Connections
Digital Output ConnectionsDigital Output Connections
Digital Output Connections
Digital outputs are provided for check-
weighing and filling applications where
the I150 will be used to control other
devices. Refer to “Checkweighing” and
Filling and Emptying Processes” in the
OPERATION section of this manual for
instructions on using these features.
The digital outputs are accessed via a 4-
pin header which is located on the compo-
nent side of the display circuit board (see
diagram).
Use the setpoint connector provided in
the accessory kit, and a suitable cable for
connecting to the header. The cable must
be round to fit properly through one of the
liquid tight connectors.
1. Locate the 4-pin header on the dis-
play circuit board.
2. Pass the cable through any free liq-
uid tight connector.
3. Connect the cable wires to the socket
connector according to the pin con-
nections shown in the table.
4. Plug the setpoint connector into the
4-pin header on the display circuit
board. Make sure the connector is
properly oriented.
5. Tighten the seal bushing until resis-
tance is felt against the cable.
Output SpecificationsOutput Specifications
Output SpecificationsOutput Specifications
Output Specifications
Test
Parameter Conditions Value
V
OH
I
OH
= -2mA max. 2.4 V min.
V
OL
I
OL
= 16mA max. 0.5 V max.
Outputs are ACTIVE LOW: LED is ON,
when output is LOW (V
OL
)
Display
Circuit
Board
Header is on
component
side of circuit
board.
APPLICATION
Pin Checkweighing Filling/Emptying
1 UNDER DRIBBLE
2 GND GND
3 OVER PREACT
4 ACCEPT TARGET
PIN CONNECTIONS
475 ohms
+5V
LED
DIGITAL
OUTPUT
PIN
Page view 10