Sample Size (APW)Sample Size (APW)
Sample Size (APW)Sample Size (APW)
Sample Size (APW)
(for Auxiliary Sample Scale)(for Auxiliary Sample Scale)
(for Auxiliary Sample Scale)(for Auxiliary Sample Scale)
(for Auxiliary Sample Scale)
When an auxiliary sample scale is used
for parts counting, the sample size (sample
number of pieces) is entered and stored
using this parameter. For instructions on
using this configuration, refer to “Parts
Counting With An Auxiliary Sample Scale”
under OPERATION .
LFT NOTE:LFT NOTE:
LFT NOTE:LFT NOTE:
LFT NOTE: “APW” does not appear in the
RS-232 submenu when LFT is set to ON.
When a sample size other than zero is
entered, the RS-232 receiver is dedicated
to the sample scale only. Other incoming
RS-232 commands will not be accepted.
Setting the sample size to zero disables
the feature and permits the RS-232 inter-
face to be used with other devices.
To enter the sample size:
1. Enter the desired number using the
numeric keypad.
2. Press
ENTER to return to the RS-
232 submenu.
Auto Print FeatureAuto Print Feature
Auto Print FeatureAuto Print Feature
Auto Print Feature
When enabled, the auto print feature
causes the I150 to automatically output
data in one of three ways; continuously, at
user specified time intervals, or upon
stability of the display.
Press
UPUP or DOWN to display the
desired setting, then press ENTER
to return to the RS232 submenu
LFT NOTE:LFT NOTE:
LFT NOTE:LFT NOTE:
LFT NOTE: Only “OFF” and “On Stb” may
be selected when LFT is set to ON.
ENTERENTER
ENTERENTER
ENTER
ENTERENTER
ENTERENTER
ENTER